Waste Gas Source: The waste gas originates from the electrophoresis drying room.

Design Air Volume: The system is designed to handle an exhaust airflow of 5,500 Nm³/h.

Pollutant Concentration: The concentration of pollutants in the waste gas is approximately 500 mg/m³.

Waste Gas Components: The primary constituents include xylene, butyl acetate, and isobutanol.

Process Configuration: The treatment process involves a rotary valve Regenerative Thermal Oxidizer (RTO).

RTO Specifications: A single RTO unit with a capacity of 5,500 Nm³/h, specifically a rotary valve RTO, has been selected.

Treatment Result: Non-methane hydrocarbons (NMHC) ≤20 mg/m³.