0102030405
Sinotruk Group Jinan Howo Bus Co., Ltd
2025-01-17

Waste Gas Source: The waste gas originates from the electrophoresis drying room.
Design Air Volume: The system is designed to handle an exhaust airflow of 5,500 Nm³/h.
Pollutant Concentration: The concentration of pollutants in the waste gas is approximately 500 mg/m³.
Waste Gas Components: The primary constituents include xylene, butyl acetate, and isobutanol.
Process Configuration: The treatment process involves a rotary valve Regenerative Thermal Oxidizer (RTO).
RTO Specifications: A single RTO unit with a capacity of 5,500 Nm³/h, specifically a rotary valve RTO, has been selected.
Treatment Result: Non-methane hydrocarbons (NMHC) ≤20 mg/m³.