0102030405
SEMCORP Co., Ltd
2025-01-17

Source of Exhaust Gas: The exhaust gas originates from the organized emissions of the coating machine.
Designed Airflow: The system includes one 70,000 m³/h Regenerative Thermal Oxidizer (RTO) and two 80,000 m³/h rotary valve RTO units.
Exhaust Gas Concentration: The concentration ranges from approximately 4,000 mg/m³ to 9,000 mg/m³.
Exhaust Gas Components: Key components include acetone, among others.
Process Configuration: The process employs a rotary valve RTO combined with waste heat recovery, featuring a steam waste heat boiler.
RTO Selection: The setup comprises one 70,000 m³/h RTO and two 80,000 m³/h rotary valve RTO units.
Emission Limits
Non-methane hydrocarbons (NMHC) emissions ≤50 mg/m³.