Exhaust Gas Source: The exhaust gas originates from the curtain coating and drying processes.
Design Airflow: The system is designed for an airflow volume of 30,000 cubic meters per hour.
Exhaust Gas Concentration: The concentration of pollutants in the exhaust gas is approximately 2,000 milligrams per cubic meter.
Exhaust Gas Components: The primary constituents are xylene and toluene.
Process Configuration: The treatment process employs a three-bed Regenerative Thermal Oxidizer (RTO).
RTO Model Selection: A three-bed RTO with a capacity of 30,000 cubic meters per hour has been selected.
Treatment Outcome: The treatment ensures that non-methane hydrocarbons (NMHC) emissions are reduced to ≤ 30 mg/m³.