0102030405
Jiangyin Bondtape Technology Co., Ltd
2025-01-17

Waste Gas Source: The waste gas is emitted from the coating machine's drying ovens.
Waste Gas Volume: The exhaust airflow is 30,000 cubic meters per hour.
Waste Gas Concentration: The concentration of pollutants in the waste gas ranges from 9,000 to 12,000 milligrams per cubic meter.
Waste Gas Components: The primary constituents are ethyl acetate and toluene.
Process Configuration: The treatment process employs a rotary valve Regenerative Thermal Oxidizer (RTO) coupled with a waste heat recovery system using a steam boiler.
RTO Model Selection: A single RTO unit with a capacity of 60,000 cubic meters per hour has been selected.
Emission Limits: Non-methane hydrocarbons (NMHC)≤ 30 mg/m³, toluene emissions ≤ 15 mg/m³.