0102030405
Jiangsu Kumho Yangnong Chemical Co., Ltd
2025-01-17

Source of Waste Gas: The waste gas is generated from workshop production exhaust, unorganized emissions, tank farm venting, and solid waste warehouse replacement processes.
Waste Air Volume: 4,500 m³/h
Waste Gas Concentration: Ranges from 2,000 to 4,000 mg/m³
Waste Gas Components: The primary constituents include toluene, epichlorohydrin, acetone, butanone, xylene, and others.
Treatment Process: The treatment process involves a buffer tank, followed by processing through a Rotary Valve Regenerative Thermal Oxidizer (RTO), quench tower, alkali washing tower, and activated carbon filtration.
RTO Specifications: The RTO unit has a capacity of 10,000 Nm³/h.
Emission Limits:
- Non-methane hydrocarbons (NMHC) ≤ 60 mg/m³