Key energy-saving technologies of RTO
Yurcent's Key energy-saving technologies of Regenerative Thermal Oxidizer
(1)Casing Vacuum Insulation Technology
The "TopTank" RTO furnace body surface is designed with a vacuum insulation casing, reducing convective heat loss.“

Simulation of convective heat loss temperature field on the windward side of an ordinary RTO furnace outer wall: Heat loss is 1.4×10⁴ W/m².
The heat loss of the Dingtian RTO furnace outer wall is 0.5 × 10⁴ W/m².
(2)High-efficiency sealed high-temp bypass valve technology
High-Temperature Bypass Face Valve
Temperature difference between the upper and lower parts of the chimney, high-temperature bypass: 20°C
High-Temperature Valve Technology Iteration:
1. 2015 High-Temperature Valve: Insulation wool valve frame, Clearance seal. Insulation cotton valve frame, gap sealing
2. 2016 High-Temperature Valve: High-temperature cement valve frame, Clearance seal
3. 2019 High-Temperature Valve: Face seal

A. Valve frame upgraded to high-temperature cement A. Seal type changed from clearance seal to face seal
B. Air-cooling device added B. Anti-impact device added
(3)High-Efficiency Heat Storage Technology
High-Efficiency Heat Storage Technology Selection of Ceramic Heat Storage Materials Cordierite, Mullite, High-Alumina Honeycomb type, Plate type Density, Hydrophobicity. Installation Process of Insulation Wool Bulk density > 200 kg/m³. Uniform Distribution of Air Pressure and Temperature