Hongyuan Waterproof Technology Group Co.,Ltd

1# RTO
Waste Gas Source: The waste gas originates from the reaction kettle, production line, and oil storage tank.
Design Air Volume: The system is designed for an exhaust airflow of 35,000 cubic meters per hour.
Waste Gas Concentration: The concentration of pollutants in the waste gas is approximately 500 mg/m³.
Waste Gas Components: The primary constituents include non-methane total hydrocarbons (NMTHC), asphalt smoke, particulate matter, and benzopyrene.
Process Configuration: The treatment process involves a cyclone separator followed by tower filtration and then a rotary valve Regenerative Thermal Oxidizer (RTO).
RTO Model Selection: A single RTO unit with a capacity of 35,000 Nm³/h (negative pressure) has been selected.
Emission Limits: Non-methane hydrocarbons (NMHC) ≤ 24 mg/m³.
---
2# RTO
Waste Gas Source: The waste gas is emitted from the reaction kettle, production line, and oil storage tank.
Design Air Volume: The system is designed to handle an exhaust airflow of 50,000 cubic meters per hour.
Waste Gas Concentration: The concentration of pollutants in the waste gas is approximately 500 mg/m³.
Waste Gas Components: The primary constituents include non-methane total hydrocarbons (NMTHC), asphalt smoke, particulate matter, and benzopyrene.
Process Configuration: The treatment process consists of a cyclone separator followed by tower filtration and then a rotary valve Regenerative Thermal Oxidizer (RTO).
RTO Model Selection: A single RTO unit with a capacity of 50,000 Nm³/h (negative pressure) has been selected.
Emission Limits: Non-methane hydrocarbons (NMHC) ≤ 24 mg/m³.